Cannulation/Catheterization/Intubation

Ringer, S. K., Schmid, A., Weiss, M. et al. 2023. Non-surgical external jugular vein catheterization using an ear vein access in piglets. Laboratory Animals 57(6), 642–649.

The objective of this study was to investigate the feasibility of external jugular vein catheterization through an ear vein in piglets. Forty-six sevoflurane-midazolam anaesthetized piglets were included. External jugular vein catheterization was conducted through the...

Lambertini, C., Grandis, A., De Silva, M. et al. 2023. The spritztube: A new device for extraglottic intubation of rabbits. Animals 13(1), 156.

The Spritztube (ST) is an extraglottic airway device developed for humans. The aim of the study was to design an ST for rabbits and to evaluate its feasibility. The study was divided into two phases...

Bruce, H., Brennan, M. 2021. Does using an endotracheal tube or a supraglottic airway device result in better unassisted ventilation in rabbits? Veterinary Record 189(7), 289-290.

Both endotracheal tubes and supraglottic airway devices appear to provide adequate unassisted ventilation in anaesthetised rabbits. However, it is highly recommended that a capnograph is used with both airway devices to monitor ventilation changes, especially...